迪朗上海翻譯公司翻譯校對
二、設(shè)計條件
- Design Conditions
2.1 企業(yè)廢氣污染物狀況
2.1 Status of Enterprise Waste Gas Pollutants
噴漆量:15噸/年
Sprayed Paint Quantity: 15 tons/year
廢水水量:1~2m3/h
Waste Water Volume:1~2m3/h
廢氣風量:150000 m3/h。
Exhaust Gas Volume: 150000 m3/h.
廢氣濃度:平均21mg/m3,最高50 mg/m3
Exhaust gas concentration: ?21mg/m3 on average, maximum 50 mg/m3
排氣方式:間歇+連續(xù)
Gas Exhaust Method: intermittent & continuous
2.2 公用工程
2.2 Public Engineering
公用工程
Public Engineering
參數(shù)
Parameter
電源
power supply
三相:380V,50Hz
Three-phase: 380V, 50Hz
壓縮空氣
Compressed air
壓力:0.6MPa
Pressure: 0.6MPa
2.3 設(shè)計要求
2.3 Design Requirements
1、噴漆房用于產(chǎn)品和零部件的噴漆。
- Paint booth is used for products and parts painting.
設(shè)計時嚴格按照國家有關(guān)安全、衛(wèi)生、消防及環(huán)保等方面的標準要求執(zhí)行,結(jié)合產(chǎn)品及使用涂料現(xiàn)狀,按噴漆工藝要求作相應(yīng)調(diào)整。
The design is carried out in strict accordance with the relevant national standards for safety, health, fire protection and environmental protection. Combining with the current situation of the product and the using coatings, corresponding adjustments are made according to the requirements of the painting process.
2、具有防燃、防爆裝置,符合GB14444-2006《噴漆室安全技術(shù)規(guī)定》與 GB5008-1992《爆炸和火災(zāi)危險場所電力裝置設(shè)計規(guī)范》要求。
- Equipped with anti-combustion and explosion-proof devices, and meets the requirements of GB14444-2006 “Safety Technical Regulations for Paint Booth” and GB5008-1992 “Specification for Design of Electrical Devices in Explosive and Fire Hazardous Locations”.
所有電氣設(shè)備都有可靠接地,其防護等級和絕緣等級滿足國家相關(guān)標準要求
All electrical equipment has reliable grounding, and the protection level and insulation level meet the requirements of relevant national standards
3、噴漆房的噪音[80db(A)以下]、廢氣等排放達到國家和上海對機械工廠設(shè)計的有關(guān)環(huán)保要求。
- The noise [80db(A) or below] and exhaust gas emission of the paint booth meet the relevant environmental protection requirements of China and Shanghai for the design of machinery factories.
4、充分考慮設(shè)備運行的安全性,在壓力控制方面均采用可靠的控制方式, 以保證設(shè)備的整體性能和質(zhì)量。
- Fully considering the safety of equipment operation, we adopt reliable control methods in pressure control to ensure the overall performance and quality of the equipment.
各系統(tǒng)中有聯(lián)鎖互動的安全裝置,確保設(shè)備、人身安全;
There are interlocking and interactive safety devices in each system to ensure equipment and personal safety.
5、設(shè)備美觀大方,滿足產(chǎn)品使用要求,運行可靠,操作簡便,維護保養(yǎng)方便易行。
- The equipment is beautiful and elegent, which meets the requirements of reliable, simple operation, convenient and easy maintenance.
6、選用的配套件、材料及電器元件均質(zhì)量可靠,技術(shù)領(lǐng)先,確保設(shè)備的整體性能和使用質(zhì)量。
- The selected parts, materials and electrical components are of reliable quality and leading technology to ensure the overall performance and quality of the equipment.
7、本項目廢氣的處理效果與所需能耗跟生產(chǎn)過程有著較大的聯(lián)系,需要保持廢氣的濃度跟風量處于相對穩(wěn)定的范圍內(nèi)才使整個系統(tǒng)更好的運行,這樣會在達到排放規(guī)范和標準的同時,又可最大程度的節(jié)約能源。
- The waste gas treatment effect of this project is closely related to the required energy consumption and the production process. It is necessary to keep the concentration and air volume of the waste gas within a relatively stable range to make the entire system work better, which needs to meet the emission standards and energy saving aim.
三、凈化系統(tǒng)設(shè)計工藝及裝置組成
- Design Process of Purification System ?and Device Components
3.2 本方案制定的原則
3.2 Principles of This Plan
1、依據(jù)國家和當?shù)赜嘘P(guān)環(huán)保法律、法規(guī)及產(chǎn)業(yè)政策要求對工業(yè)污染進行治理,充分發(fā)揮建設(shè)項目的社會效益、環(huán)境效益和經(jīng)濟效益。
- Industrial pollution must be treated In accordance with the requirements of national and local environmental protection laws, regulations and industrial policies. The social, environmental and economic benefits of the construction project shall be brought into full play.
2、積極穩(wěn)妥地采用新技術(shù)、新設(shè)備,結(jié)合企業(yè)的現(xiàn)狀和管理水平采用先進、可靠的改造技術(shù)和污染治理工藝,力求運行穩(wěn)定、費用低、管理方便、維護容易,從而達到治理污染、保護環(huán)境的目的。
- Actively and steadily adopt new technologies and equipment with advanced and reliable ?reconstruction technologies and pollution control process based on the current status and management level of the enterprise. Strive to achieve stable operation, low cost, convenient management and easy maintenance, so as to realize pollution control and environment protection.
3、妥善解決項目建設(shè)及運行過程中產(chǎn)生的污染物,避免二次污染。
- Properly solve the pollutants generated during the construction and operation of the project to avoid secondary pollution.
4、嚴格執(zhí)行現(xiàn)行的防火、安全、衛(wèi)生、環(huán)境保護等國家和地方頒布的規(guī)范、法規(guī)與標準。
- Strictly implement the current national and local regulations and standards for fire prevention, safety, health and environmental protection.
5、選擇新型、高效、低噪設(shè)備、注意節(jié)能降耗。
- Choose new type, high-efficiency, low-noise equipment, and pay attention to energy saving.
3.3 本方案治理的基本目標
3.3 The Basic Goals of ?This Program
清洗房廢水:
Waste water from Cleaning booth:
根據(jù)國家相關(guān)規(guī)定應(yīng)首先考慮按上海市廢氣排放的有關(guān)標準進行治理效果的綜合監(jiān)測驗收,目標是噴漆室負壓、密閉,收集效率 95%以上;達到VOCs排放濃度在70mg/m3以下,凈化效率>95%的標準要求。
According to the relevant national regulations, the comprehensive monitoring and acceptance of the treatment effect should be considered in accordance with the relevant standards of Shanghai waste gas emission. The goal is to have a negative pressure and airtightness paint booth, with a collection efficiency of more than 95%, to achieve the VOCs emission concentration below 70mg/m3, and the purification efficiency above 95% of the standard requirements.
3.4 工藝選擇路線
3.4 Process Selection
根據(jù)業(yè)主未來的生產(chǎn)規(guī)劃及特點,其廢氣適宜于采用濃縮+燃燒系統(tǒng)進行處理,而對于業(yè)主的間歇式生產(chǎn)特點,燃燒系統(tǒng)適宜選用催化燃燒方式(CO),但濃縮段工藝有沸石及活性碳濃縮兩種,對于選用何種方式現(xiàn)做出如下對比:
According to the owner’s future production plan and characteristics, the exhaust gas is suitable for treatment with a concentration and combustion system. For the owner’s intermittent production characteristics, the combustion system is suitable for Catalytic Oxidizer (CO), however the concentration selections includes zeolite and activated carbon. the following comparison are made for decision.
對比項
Items for Comparison
沸石濃縮工藝
Zeolite concentration process
活性碳濃縮工藝
Activated carbon concentration process
備注
Remarks
安全性
Safety
沸石本身為不可燃,正常運行情況下不會出現(xiàn)燃燒情況。
Zeolite is non-flammable and will not burn under normal operating conditions.
活性碳本身為可燃物,并且活性碳在吸附有機物質(zhì)時還會產(chǎn)生吸附熱,如果碳層或者氣流不均勻,將會造成局部溫度急劇升高點燃活性碳從而造成連鎖燃燒;另外脫附過程中如果升溫過快也會造成燃燒。
The activated carbon is combustible, and the activated carbon will also generate adsorption heat in adsorbing organic substances. If the carbon layer or the air flow is not uniform, it will cause the partial temperature rising sharply to ignite the activated carbon and result in chain combustion. In addition, during the desorption process, If the temperature rises too fast, it will also get burning.
濃縮倍率
Concentration rate
25~30
25~30
5
5
由于活性碳如果脫附風量過小,容易造成散熱不佳,影響系統(tǒng)安全性,所以濃縮倍率無法提升
If the desorption air volume of activated carbon is too small, it is easy to cause poor heat dissipation and infulence the safety of the system, so the concentration rate cannot be increased.
系統(tǒng)處理效率
System processing efficiency
吸附凈化效率95%以上
The adsorption purification efficiency above 95%
吸附凈化效率85%以上
Adsorption purification efficiency above 85%
系統(tǒng)運行穩(wěn)定性
System operation stability
沸石濃縮+燃燒系統(tǒng)無需切換管道,可以通過PLC控制,并且根據(jù)各點位的溫度監(jiān)控,實時調(diào)節(jié)風量配比,達到最穩(wěn)定、節(jié)能的運行狀態(tài)
The zeolite concentration and combustion system does not need to switch pipelines, and can be controlled by PLC, and according to the temperature monitoring of each point, the air volume ratio can be adjusted in real time to achieve the most stable and energy-saving operation state
活性碳濃縮+燃燒系統(tǒng)使用多個活性碳吸附器并聯(lián),定時切換吸脫附管,需使用大量切換閥門,而且脫附時間長,需要系統(tǒng)長時間保持運行狀態(tài),否則容易出現(xiàn)脫附不完全造成吸附效果不達標。
The activated carbon concentration and combustion system uses multiple activated carbon adsorbers in parallel. Switching the adsorption and desorption pipes regularly, requires a large number of switching valves, and long desorption time. The system needs to be kept in operation for a long time, otherwise it is easy to cause incomplete desorption and result in the adsorption effect not up to standard.
占地面積
The Footprint
100m2
100m2
143m2
143m2
上下雙層布局
Layout with up and down double layer
耗材更換頻率
Replacement frequency of consumables
沸石材料使用壽命一般在5~7年
The service life of zeolite materials is generally 5 to 7 years
活性碳顆粒由于本身強度,在使用過程中不可避免的會出現(xiàn)摩擦破碎,造成損失,并且由于脫附過程中會存在死區(qū),所以整體壽命一般不會超過1年。
Due to the strength of activated carbon particles, friction and breakage will inevitably occur during use and causing losses. Because there will be dead zones in the desorption process, the overall life span generally does not exceed 1 year.
預(yù)處理過濾器均為每季度更換一次
The pretreatment filter is replaced every quarter
系統(tǒng)維護
system maintenance
沸石裝置更換簡便,只需1~2人即可完成,每1~2年可以對沸石進行采樣檢測,確認沸石劣化情況,若有需要,可以進行再生作業(yè),保證使用壽命。
The zeolite device is easy to be ?replaced and can be completed by just 1 or 2 person. The zeolite must be sampled and tested every 1 or 2 years to confirm the deterioration of the zeolite. If necessary, regeneration can be carried out to ensure the service life.
如果出現(xiàn)局部沸石材料損壞可以快速修復(fù),不會影響生產(chǎn)。
If partial zeolite material damage occurs, it can be repaired quickly without stopping production.
活性碳更換工作量大,每次需要更換13噸左右活性碳,需要吊車及機械搬運工具輔助,并且容易造成周邊環(huán)境二次污染;更換下來的飽和活性碳為環(huán)保重點管理的危險廢棄物,需要委托專業(yè)單位進行處置,而現(xiàn)在危廢處置單位的處置量有限,可能會出現(xiàn)需要排隊無法及時處置的現(xiàn)象,這種情況下未能及時處置的飽和活性碳需要存放在專用的危廢存放區(qū)。
Activated carbon replacement is a heavy workload, about 13 tons of activated carbon needs to be replaced each time, which requires the assistance of cranes and mechanical handling tools, and is likely to cause secondary pollution to the surrounding environment. the replaced saturated activated carbon is a hazardous waste regulated by environmental protection administration. Professional organizations are entrusted for disposal, and now the disposal capacity of the organization is limited, and there may be a phenomenon that needs to be queued and the waste cannot be disposed in time. In this situation, undisposed saturated activated carbon must be stored in a dedicated hazardous waste storage area.
燃燒裝置運行維護部分基本相同
The operation and maintenance of the combustion device is basically the same
根據(jù)以上比較,從安全可靠、運行穩(wěn)定、節(jié)能、易于維保、占地面積小及無二次污染等方面綜合考慮,沸石濃縮裝置更適合業(yè)主的實際需求,所以我方推薦的處理工藝流程為沸石濃縮+催化燃燒工藝。
Based on the above comparison, considering the safety and reliability, stable operation, energy saving, easy maintenance, small footprint and no secondary pollution, the zeolite concentration device is more suitable for the actual needs of the owner, so the treatment process we recommend is Zeolite concentration and catalytic combustion process.
3.5 濃縮裝置樣式選擇
3.5 Concentration Device Selection
對于本項目風量大、濃度低,需要選用一種吸附穩(wěn)定、濃縮倍率高、性價比良好的吸附材料。
For this project with large air volume and low concentration, it is necessary to select an adsorption material with stable characteristic, high concentration rate and cost-effective.
現(xiàn)在常見的沸石濃縮裝置使用的吸附材料主要有日系和歐美系產(chǎn)品,其中日系產(chǎn)品濃縮倍率高、使用范圍廣,案例多更為符合本項目的需求。
The adsorption materials used in common zeolite concentration devices are mainly made in Japan, Europe and US. Japanese products have a high concentration rate and a wide range of applications. Many cases are in line with the needs of this project.
另外日系沸石濃縮裝置又可以分為轉(zhuǎn)輪結(jié)構(gòu)及傳統(tǒng)結(jié)構(gòu)兩類,其吸附裝置運行結(jié)構(gòu)、使用的沸石種類均有比較不同的特性,對于本項目使用何種樣式的濃縮裝置更適合業(yè)主的實際需求,先做出一下比較:
In addition, the Japanese zeolite concentration device can be divided into two types: the wheel structure and the traditional structure. The operation structure of the adsorption device and the type of zeolite used have different characteristics. Which type of concentration device will be used in this project to meet the actual situation of the owner will be discussed in the following comparison:
3.5.1結(jié)構(gòu)原理
3.5.1 Structural Principle
轉(zhuǎn)輪型
Wheel type
轉(zhuǎn)筒型
Drum type
沸石材料結(jié)構(gòu):圓盤或扇型式
Zeolite material structure: disc shape or fan shape
安裝方式:圓盤中心安裝轉(zhuǎn)軸,固定于兩側(cè)支架軸承上
Installation method: install the shaft in the center of the disc, and fix it on the bearings of the brackets on both sides
旋轉(zhuǎn)方式:沿水平軸旋轉(zhuǎn)
Rotation method: Turning around the horizontal axis
轉(zhuǎn)輪分區(qū):分為吸附、脫附及冷卻區(qū)
Wheel zoning: divided into adsorption zone, desorption zone and cooling zone
分區(qū)密封方式:密封條安裝與分區(qū)隔板上,運行時刮擦轉(zhuǎn)盤表面密封
Sealing method of zones: the sealing strip is installed on the baffle plate , and the surface of the disc is scratched by sealing during operation
工藝流程:1.廢氣經(jīng)過吸附區(qū)后凈化排放
Process flow: 1. Waste gas is purified and discharged after passing through the adsorption zone
2.脫附熱風吹過脫附區(qū)后,吹出的濃縮氣體進入燃燒裝置
- After the desorption hot air blows through the desorption zone, the blown out concentrated gas enters into the combustion device.
3.取新風吹過冷卻區(qū),對完成脫附的沸石降溫,冷卻區(qū)出風進行進一步升溫后作為脫附熱風進入脫附區(qū)
- Blow fresh air through the cooling zone to cool down the desorpted zeolite. The air from the cooling zone will be further heated and then enter into the desorption zone as desorption hot air.
沸石材料結(jié)構(gòu):模塊式(紅圈)
Zeolite material structure: modular (red circle)
安裝方式:模塊安裝與鋼結(jié)構(gòu)轉(zhuǎn)筒內(nèi)部固定槽中
Installation method: module installation and fixed on groove in the steel drum
旋轉(zhuǎn)方式:沿垂直軸旋轉(zhuǎn)
Rotation method: Rotating around the vertical axis
轉(zhuǎn)輪分區(qū):分為吸附及脫附區(qū)
Wheel zoning: divided into adsorption zone and desorption zone
分區(qū)密封方式:密封條安裝于模塊鋼結(jié)構(gòu)轉(zhuǎn)同上,運行過程中刮擦分區(qū)隔板表面密封。
Sealing method of zoning: The sealing strip is installed on the modular steel drum, and the scratched zoning baffle plate surface is sealed in operation.
工藝流程:1.廢氣經(jīng)過吸附區(qū)后凈化排放
Process flow: 1. Waste gas is purified and discharged after passing through the adsorption zone
- 取新風加熱作為脫附熱風吹過脫附區(qū)后,吹出的濃縮氣體進入燃燒裝置
- Heating fresh air as desorption hot air and blow through the desorption zone. Then the blown out concentrated gas enters into the combustion device
3.5.2性能比較
3.5.2 Performance Comparison
對比項
Items for Comparison
轉(zhuǎn)輪型
Wheel type
轉(zhuǎn)筒型
Drum type
備注
Remarks
吸附材料沸石含量
Zeolite content of adsorbent
50%
50%
75~80%
75~80%
生產(chǎn)工藝不同
Different production processes
脫附溫度
Desorption temperature
180~220℃由于模塊中含有較多基材,基材吸收的熱量不會起到脫附的作用,所以需要更多的熱量;而且基材存熱過多,脫附完成后必需冷卻后才能進入吸附階段
180~220℃ Because the module contains more substrates, the heat absorbed by the substrate will not play a role in desorption, so more heat is needed. for this reason, the substrate must be cooled after desorption for adsorption stage.
150~180℃由于沸石含量高所以整體熱能利用率高,吸附材料存熱少,所以可以使用較低脫附溫度,并且脫附完成無需冷卻可直接進入吸附階段
150~180℃ Because of the high zeolite content, the overall heat energy utilization rate is high, and the adsorption material has less heat storage, so a lower desorption temperature can be used, and directly get into the adsorption stage without cooling after desorption.
濃縮倍率
Concentration rate
15~20倍
15-20 times
20~33倍
20~33 times
單臺設(shè)備最大處理風量
Maximum processing air volume of a single device
100000m3/h
100000m3/h
200000m3/h
200000m3/h
由于傳統(tǒng)轉(zhuǎn)盤結(jié)構(gòu)強度限制,無法做的過大
Due to the structural strength limit of the traditional disc type, it cannot be made too large
單臺最大占地面積
Maximum footprint of a single unit
12m2
12m2
12m2
12m2
占地面積相同但處理風量相差1倍
The footprint is the same but the air volume is 1 times different
吸附材料更換方式
Absorption material replacement method
更換以整個或半個轉(zhuǎn)輪為單位進行,需要起重機械配合,并且更換時間較長,若無備用系統(tǒng)需要長時間停產(chǎn)配合
The replacement is carried out in the whole or half of the wheel, which requires the cooperation of hoisting machinery, and the replacement time is long. If there is no backup system, it will take a long time to stop production.
以模塊化吸附單元塊為單元進行更換,無需特殊設(shè)備配合,1~2人使用簡單工具即可更換,而且更換速度快,可在生產(chǎn)換班或短時間內(nèi)完成
In the condition that the modular adsorption unit block is used for replacement, no special equipment is needed, and it can be replaced by 1 or 2 persons with simple tools, and the replacement speed is fast, which can be completed during a production shift or within a short rest.
運行穩(wěn)定性
Operational stability
由于密封條運行過程中密封條與沸石表面產(chǎn)生接觸摩擦,可能會造成永久損傷,同時在轉(zhuǎn)輪表面產(chǎn)生VOC累積,可能會產(chǎn)生一定的安全問題
Due to the contact friction between the sealing strip and the surface of the zeolite during the operation, permanent damage may be caused. At the same time, the accumulation of VOC on the surface of the wheel may cause certain safety problems.
運行過程中密封條與沸石表面不發(fā)生接觸,避免了可能會造成的沸石損傷
During operation, the sealing strip does not contact with the surface of the zeolite, which avoids possible damage to the zeolite
3.5.3性價比
3.5.3 Cost-effective
對比項
Items for Comparison
轉(zhuǎn)輪型
Wheel type
轉(zhuǎn)筒型
Drum type
備注
Remarks
吸附材料使用量
Adsorption material usage
100%
100%
70%
70%
同等工況下,轉(zhuǎn)筒濃縮沸石投資成本大于傳統(tǒng)轉(zhuǎn)盤5%
Under the same working conditions, the investment of rotary drum concentrated zeolite is 5% higher than that of the traditional rotary wheel type
吸附材料價格
Adsorbent price
100%
100%
150%
150%
吸附材料使用壽命
Service life of adsorption material
N年
N years
1.5~2N年
1.5~2N years
使用壽命是傳統(tǒng)吸附材料1~2倍,平均每年吸附耗材費用為傳統(tǒng)的50%
The service life is 1~2 times of traditional adsorption materials, and the average annual cost of adsorption consumables is 50% of traditional adsorption materials.
單臺設(shè)備最大處理風量
Maximum processing air volume of a single device
100000m3/h
100000m3/h
200000m3/h
200000m3/h
對于100000m2/h以上處理量的工程,轉(zhuǎn)筒濃縮可以做到單臺處置,無需設(shè)置兩臺,節(jié)約投資成本。
For the project with a processing capacity of more than 100,000 m2/h, it can be handled by a single rotary drum concentration unit without backup, which saves investment costs.
濃縮倍率
Concentration rate
15~20倍
15-20 times
20~33倍
20~33 times
轉(zhuǎn)筒濃縮倍率高,可以保證后續(xù)燃燒裝置投資為傳統(tǒng)轉(zhuǎn)盤濃縮的60%
The rotary drum has a high concentration ratio, which can ensure that the subsequent combustion device investment is 60% that of the traditional rotary wheel concentration uint.
3.5.4結(jié)論
3.5.4 Conclusion
根據(jù)以上多方面比較得出,轉(zhuǎn)筒型在濃縮倍率、投資成本、運行節(jié)能以及后期維護等方面均有比較明顯的優(yōu)勢,也更為符合本項目濃縮倍率高、節(jié)能穩(wěn)定及維保簡便等需求,所以此次項目的最終工藝選擇為沸石轉(zhuǎn)筒濃縮+催化燃燒工藝。
According to the comparison of the above aspects, the drum type has obvious advantages in concentration ratio, investment cost, operation energy saving, and later maintenance. It is more in line with the needs of this project for high concentration ratio, stable energy saving and easy maintenance. Therefore, the final process of this project is selected as the zeolite drum concentration and catalytic combustion process.
3.6 有機廢氣沸石轉(zhuǎn)筒吸附—催化燃燒系統(tǒng)簡介
3.6 Introduction to The Organic Waste Gas Zeolite Drum Adsorption Catalytic Combustion System
根據(jù)業(yè)主有機廢氣的相關(guān)參數(shù)及相關(guān)的處理要求,我們采用轉(zhuǎn)輪濃縮+催化燃燒的方式進行處理。
According to the relevant parameters of the owner’s organic waste gas and treatment requirements, we adopt the method of rotary wheel enrichment and catalytic combustion for treatment.
簡易流程如下:
The brief process is as follows:
有機廢氣經(jīng)管道收集進入前置過濾器過濾和冷凝降溫等設(shè)備進行預(yù)處理以后,進入沸石轉(zhuǎn)筒裝置吸附處理區(qū)進行凈化處理,進入濃縮轉(zhuǎn)筒的有機廢氣(上圖,下同)在常溫下被轉(zhuǎn)筒吸附區(qū)吸附凈化后直接排放至大氣(最高凈化效率可達95%)(),接著因轉(zhuǎn)筒的轉(zhuǎn)動而進入脫附區(qū),吸附了有機物質(zhì)的轉(zhuǎn)筒在脫附區(qū)內(nèi)被150-180℃小風量脫附(高倍濃縮)、高濃度小風量廢氣()進入催化燃燒處理系統(tǒng)。
The organic waste gas is collected through the pipeline and enters into the pre-filter and condensation cooling equipment for pretreatment, and then enters into the adsorption treatment zone of the zeolite drum device for purification treatment. The organic waste gas entering the concentration drum (as the above picture and the same as below) to be adsorpted and purified in the drum adsorption zone, then directly discharged to the atmosphere (the highest purification efficiency can reach 95%), ?then enters the desorption zone due to the rotation of the drum. the adsorpting drum will be desorpted by180°C small air volume (high concentration), high concentration and small air volume exhaust gas () enter the catalytic combustion treatment system.
廢氣只要被加熱到280-350℃,進入催化床就能被催化分解成水和二氧化碳后放熱成為高溫清潔氣體(),溫度交換后排入大氣。
As long as the exhaust gas is heated to 280-350℃, it can be catalytically decomposed into water and carbon dioxide when it enters the catalyst bed, it releases heat to become a high-temperature clean gas and is discharged into the atmosphere after temperature exchange.
其中催化燃燒是典型的氣-固相催化反應(yīng),其實質(zhì)是活性氧參與的深度氧化作用。
The catalytic combustion is a typical gas-solid phase catalytic reaction, and the essence is the deep oxidation with active oxygen.
在催化燃燒過程中,催化劑的作用是降低活化能,同時催化劑表面具有吸附作用,使反應(yīng)物分子富集于表面提高了反應(yīng)速率,加快了反應(yīng)的進行。
In the process of catalytic combustion, the role of the catalyst is to reduce the activation energy, at the same time, the surface of the catalyst has an adsorption effect, so that the reactant molecules are concentrated on the surface to increase the reaction rate and accelerate the reaction.
借助催化劑可使有機廢氣在較低的起燃溫度條件下,發(fā)生無焰燃燒,并氧化分解為CO2和H2O,同時放出大量熱能,其反應(yīng)過程為:
With the help of a catalyst, the organic waste gas can undergo flameless combustion at a lower ignition temperature, and be oxidized and decomposed into CO2 and H2O, meanwhile a large amount of heat energy is released. The reaction process is as follow:
四、主要設(shè)備說明
- Description of Main Equipment
4.1設(shè)備房房體
4.1 Equipment Booth Booth Body
1.噴漆房外形尺寸:L14000×W9000×H8000mm;
- Overall dimensions of paint booth: L14000×W9000×H8000mm;
L14000×W6000×H8000mm;
L14000×W6000×H8000mm;
噴漆房數(shù)量:2間;
Number of paint booths: 2 booths;
噴房漆霧收集方式:頂部進風,側(cè)面排風;
Collection method of paint mist in the paint booth: ?inlet air from the top, and exhaust air from side wall.
噴漆房墻體:方鋼管龍骨+75mm彩鋼巖棉板,內(nèi)襯1.5mm厚不銹鋼;
Paint booth wall: square steel pipe keel and 75mm color steel rock wool board, lined with 1.5mm thick stainless steel;
噴漆房前后兩端各設(shè)置一套卷簾門,工件進出大門呈通過式,大門規(guī)格為:W7000×H7500mm/ W4000×H7500mm,每扇門上各設(shè)三個觀察窗,材質(zhì)雙層PVC布加保溫層,電機防爆,柔性堆積門,并在每座噴漆房中部設(shè)置伸縮隔斷,材質(zhì)阻燃PVC布,電機防爆;
There are a set of rolling shutter doors at the front and back ends of the paint booth. The workpiece pass-through the doors. The size of the doors are: W7000×H7500mm/ W4000×H7500mm. Each door is equipped with three observation windows. The motor is explosion-proof, flexible stacking doors, and a telescopic partition is set in the middle of each paint booth, the material is flame-retardant PVC cloth, and the motor is explosion-proof;
噴漆室北側(cè)前后兩端設(shè)置緊急逃生門: W1000×H2000mm,外開;
Emergency escape doors are set at the front and rear ends of the north side of the paint booth: W1000×H2000mm with doors opened to the outside.
噴漆室兩側(cè)前后兩端各設(shè)置一輛軌道式升降車,電機防爆,行走7米,高度7米,伸縮3米;
A rail-mounted lift truck is installed at the front and rear ends of the paint booth with 7 meters walking route, 7 meters lifting height, and 3 meters telescopic. and the motor is explosion-proof ;
排風管道為1.2mm厚鍍鋅鋼板,保溫回風管道為1.2mm厚鍍鋅鋼板外襯50mm厚保溫棉及0.5mm厚鍍鋅鋼板襯板
The exhaust duct is 1.2mm thick galvanized steel sheet, and the heat preservation aire return duct is 1.2mm thick galvanized steel sheet, which is lined with 50mm thick insulation cotton and 0.5mm thick galvanized steel liner sheet.
給氣風機:低噪音風扇,變頻控制;
Air supply fan: low noise fan with frequency conversion control.
加熱除濕系統(tǒng),采用電加熱新風除濕系統(tǒng),保證噴漆室內(nèi)溫度可在 40-60℃范圍內(nèi)穩(wěn)定控制,相對濕度需穩(wěn)定控制在RH75 %以下;
Heating dehumidification system, with the electric heating fresh air dehumidification system to ensure that the temperature in the painting room can be stably controlled within the range of 40-60℃, and the relative humidity must be stably controlled below RH75%;
照明系統(tǒng)采用具有隔爆性能燈箱, ?燈箱安裝在墻體上,密封效果好,滿足防塵及防爆要求。
The illumination system adopts a explosion-proof light box, which is installed on the wall with good sealing and meets the requirements of dust-proof and explosion-proof.
室內(nèi)光照度達 600Lux 以上,房內(nèi)光線柔和,光照均勻明亮,無照射死角;
The indoor illuminance is above 600Lux, the light in the booth is soft, uniform and bright without blind spot.
控制系統(tǒng)采用手動控制 、自動控制兩種模式,顯示:風機、馬達運轉(zhuǎn)狀態(tài)、電機運轉(zhuǎn)狀態(tài)(Hz)、 風機壓差值(ON/OFF)、設(shè)備運轉(zhuǎn)狀態(tài)與進出口壓差值、各點溫度、電磁閥狀況(開/ 關(guān))、報警信息等,另外控制系統(tǒng)還有一系列監(jiān)控感應(yīng)器并采取一系列措施保證生產(chǎn)安全:a. 室內(nèi)安裝可燃氣體報警器(大門側(cè)1米處),室內(nèi)可燃氣體濃度超過過爆炸下限(LEL)的25%時,噴室強制排風,并持續(xù)聲光報警,室內(nèi)可燃氣體濃度達到爆炸下限50%時,系統(tǒng)互鎖自動關(guān)閉噴漆作業(yè);b.安裝風速測速儀,測定風速,當風速低于設(shè)定值聲光報警。
The control system adopts two modes as manual control and automatic control with displaying fan and motor running status, motor running status (Hz), fan pressure difference (ON/OFF), equipment running status, inlet and outlet pressure difference, temperatures at each point, solenoid valve status (open/close), alarm information and etc. In addition, the control system also has a series of monitoring sensors and measures to ensure production safety.a. Install a indoor combustible gas alarm (1 meter from the gate side). When the indoor combustible gas concentration exceeds 25% of the lower explosion limit (LEL), the paint booth will be forced to exhaust, and the sound-light alarm will occurs continuously. When the indoor combustible gas concentration reaches 50% of the explosion lower limit. the system interlocks is triggered and automatically shuts down the painting operation. b. Install an anemometer to measure the wind speed, when the wind speed is lower than the set value, sound and light alarm ?occurs.
由于開口要求風速較低(不低于0.5m/s),容易受環(huán)境干擾,影響測定精度,因此可通過測量排風總風量推算截面風速方法;c.噴涂機與排風機設(shè)計連鎖,當排風機未開啟或排風管道內(nèi)風速不達標時噴涂機無法開啟。
Since the air outlet requires a low wind speed (no less than 0.5m/s), it is easily affected by environmental interference and disturb the measurement accuracy. Therefore, the cross-sectional wind speed can be calculated by measuring the total exhaust air volume; c. The painter and the exhaust fan are designed to be interlocked, therefore the painter cannot be initiated if the fan is not turned on or the wind speed in the exhaust duct is not up to the standard.
同時壓縮空氣管道安裝流量計及密閉閥,實時檢測壓縮空氣用量,當廢氣排風風量不滿足要求是自動斷開壓縮空氣供給;d.室內(nèi)設(shè)計安裝2套溫控探頭,用于檢測室內(nèi)溫度,當室內(nèi)溫度超過設(shè)定值,持續(xù)聲光報警并噴漆設(shè)備停止工作。
At the same time, the compressed air pipeline is equipped with a flow meter and a closed valve to detect the amount of compressed air in real time. When the exhaust air volume does not meet the requirements, the compressed air supply is automatically cut off; d. ?2 sets of temperature control probes is installed indoor to detect the indoor temperature. When the indoor temperature exceeds the set value, the sound and light alarm will occured continusouly and the painting equipment will stop working.
需手動復(fù)位重新工作。
the system can be reset manually to work again.
系統(tǒng)實時記錄兩套溫控探頭溫度;e. 在房體安全門上安裝有壓力保護裝置,當房內(nèi)空氣壓力大于 1300Pa 壓力值時,安全門將自動打開泄壓,以保證操作人員安全。
The system records the temperature of two sets of temperature control probes in real time; e. A pressure protection device is installed on the safety door of the booth. When the air pressure in the booth is more than 1300Pa, the safety door will automatically open and release the pressure to ensure the safety of the operator.
同時所有電氣設(shè)備均采用帶過載保護、短路保護及斷相保護的線路設(shè)計,一旦發(fā)生設(shè)備故障報警,整個噴漆系統(tǒng) ?停止工作。
At the same time, all electrical equipment adopts circuit design with overload protection, short circuit protection and phase failure protection. Once equipment failure alarm occurs, the entire painting system stops working.
2.清洗房外形尺寸:L8000×W9000×H8000mm
- Dimensions of cleaning booth: L8000×W9000×H8000mm
清洗房數(shù)量:1間
Number of cleaning booth: 1 booth
清洗房墻體:方鋼管龍骨+75mm彩鋼巖棉板,內(nèi)襯1.5mm厚不銹鋼;
Cleaning booth wall: square steel pipe keel + 75mm color steel rock wool board, lined with 1.5mm thick stainless steel;
噴漆室前后兩端各設(shè)置一套卷簾門,工件進出大門呈通過式,大門規(guī)格為: W7000×H7500mm,材質(zhì)雙層PVC布加保溫層,電機防爆,柔性堆積門,每扇門上各設(shè)至少三個觀察窗;
There are 2 sets of rolling shutter doors each at the front and back ends of the paint booth. The workpiece pass-through the doors. The size of the door is: W7000×H7500mm, double-layer PVC cloth with insulation layer, explosion-proof motor, and flexible stacking doors. Each door has at least three Observation windows
清洗房北側(cè)前后兩端設(shè)置緊急逃生門: W1000×H2000mm,外開;
Emergency escape doors are set at the front and rear ends of the north side of the Cleaning booth: W1000×H2000mm, with opening to the outside;
清洗房兩側(cè)各設(shè)置一輛軌道式升降車,電機防爆,行走7米,高度7米,伸縮3米;
There is a rail-mounted lift truck on each side of the cleaning booth, the motor is explosion-proof, with 7 meters walking route, 7 meters lifting height, and 3 meters telescopic;
照明系統(tǒng)采用具有隔爆性能燈箱, ?燈箱安裝在墻體上,密封效果好,滿足防塵及防爆要求。
The illumination system adopts a explosion-proof light box, which is installed on the wall with good sealing and meets the requirements of dust-proof and explosion-proof.
室內(nèi)光照度達 600Lux 以上,房內(nèi)光線柔和,光照均勻明亮,無照射死角;
The indoor illuminance is above 600Lux, the light in the booth is soft, uniform and bright without blind spot.
污水處理方案:凈化后循環(huán)使用。
Sewage treatment plan: recycling after purification.
3.工程實例及常用材料合格證書
- Engineering examples and certificates of common materials
4.2 電解污水處理裝置
4.2 Electrolysis Sewage Treatment Device
清洗房產(chǎn)生廢水中主要含有灰塵、清洗劑及液壓油等污染物,根據(jù)業(yè)主實際需求及前期溝通,本次通過實驗確認之前提出的廢水循環(huán)使用的可行性并確定設(shè)備規(guī)格。
The waste water produced in the Cleaning booth mainly contains pollutants such as dust, cleaning agent and hydraulic oil. According to the actual needs of the owner and the preliminary communication, this experiment confirm the feasibility of the previously proposed waste water recycling and determine the equipment specifications.
4.2.1實驗
4.2.1 Experiment
1.廢水狀態(tài):本次實驗采用業(yè)主提供的廢水樣品,廢水呈淡黃色、略渾濁(見圖片1)
- Waste water status: in this experiment will uses the waste water sample provided by the owner, and the waste water is light yellow and slightly turbid (see picture 1)
2.實驗一:使用小型電解實驗裝置對廢水進行電解處理并觀察廢水變化及測試電導(dǎo)率(單位μs/cm),實驗開始30分鐘后,廢水上部出現(xiàn)明顯浮渣,水體開始變白變清,電導(dǎo)率略有上升為22.7(見圖片2);1小時后浮渣繼續(xù)增加,電導(dǎo)率為42(見圖片3);2小時后電導(dǎo)率上升至96.9(見圖片4)。
- Experiment 1: Use a small electrolysis experimental device to electrolyze the waste water and observe the changes in the waste water and test the conductivity (unit: μs/cm). 30 minutes after the start of the experiment, obvious scum appears in the upper layer of the wastewater, and the water body begins to become white and clear. the conductivity slight increase to 22.7 (see picture 2); ?1 hour later, the scum continued to increase, and the conductivity was 42 (see picture 3); 2 hours later, the conductivity rose to 96.9 (see picture 4).
3.實驗二:將電解后的廢水與原始廢水混合,模擬循環(huán)混合狀態(tài),混合后水體電導(dǎo)率為37.8(見圖片5);凈化1小時候電導(dǎo)率上升為121.6(見圖片6),凈化后的水體基本無色透明(見圖片7),將中部水體取出靜置后,會有部分絮體沉降產(chǎn)生(見圖片8),水體電導(dǎo)率下降為72.5(見圖片9)。
- Experiment 2: Mix the electrolyzed wastewater with the original wastewater to simulate the cyclic mixing state. After mixing, the conductivity of the water is 37.8 (see picture 5); the conductivity rises to 121.6 (see picture 6) after purification for 1 hour. The water body is basically colorless and transparent (see picture 7). sampling the central layer water and stay still, some flocs will settle (see picture 8), and the conductivity of the water body drops to 72.5 (see picture 9).
圖片1 實驗水樣照片 ????圖片2 實驗一 ????圖片3 實驗一
Picture 1 Experimental water sample picture Picture 2 Experiment 1 Picture 3 Experiment 1
圖片4 實驗一 ???圖片5 實驗二 ???圖片6 實驗二 ???圖片7 凈化后水樣
Picture 4 Experiment 1 Picture 5 Experiment 2 Picture 6 Experiment 2 Picture 7 Purified water sample
圖片8 水體底部沉降絮體 ???????????圖片9 靜置后水體電導(dǎo)率
Picture 8 Settling flocs at the bottom of the water body Picture 9 Conductivity of the water body after staying still
4.結(jié)論:本次實驗中廢水經(jīng)過電解凈化后,水體變?yōu)闈崈?,大部分廢渣可以上浮,較易去除,而根據(jù)業(yè)主要求處理后水體電導(dǎo)率不能大于500,而此次實驗中最高電導(dǎo)率為121.6,并且靜置一段時間后電導(dǎo)率下降至72.5。
- Conclusion: After the wastewater is purified by electrolysis in this experiment, the water body becomes clean, and most of the waste residue can float up and is easier to be removed. According to the owner’s request, the conductivity of the water body after treatment ?cannot be greater than 500, and the highest conductivity in this experiment It is 121.6, and the conductivity drops to 72.5 after staying still for a period of time.
此現(xiàn)象表明實驗中的較高電導(dǎo)率的出現(xiàn),主要是由于水體中雜質(zhì)轉(zhuǎn)化為絮體后,仍有部分較輕的絮體懸浮在水體中;另外由于小型電解裝置并不是實時循環(huán),雜質(zhì)去除后仍不停有鋁離子電解進入水體,離子濃度變高造成電解率偏高。
This phenomenon shows that the higher conductivity in the experiment is mainly due to the fact that after the impurities in the water body are converted into flocs, there are still some lighter flocs suspended in the water body. In addition, because the small electrolytic device does not circulate in real time, aluminum ions are still electrolyzed into the water body after the impurities are removed , and higher ion concentration resulting in a higher electrolysis rate.
所以通過靜置后電導(dǎo)率便會下降,實際設(shè)備中的循環(huán)水箱即可達到此效果,并且實際設(shè)備會不斷有循環(huán)水進入,只需要按照廢水的實際情況設(shè)置運行時間便可以保證沒有過多離子進入水體,所以完全可以滿足業(yè)主對于循環(huán)水電導(dǎo)率的要求。
Therefore, the conductivity will drop after staying still, and the circulating water tank in the actual equipment can achieve this effect with continuously entering circulating water. We only need to set the operating time according to the actual situation of the wastewater to ensure that there are no excessive ions enter into the water body, so it can fully meet the requirements of the circulating water conductivity.
4.2.2設(shè)計方案
4.2.2 Design Plan
采用廢水循環(huán)利用方式時,前期清洗使用循環(huán)水,最后使用清水進行最后沖洗,沖洗后的廢水作為補充水進入循環(huán)系統(tǒng),設(shè)計循環(huán)系統(tǒng)處理量:5m3/d,由于現(xiàn)場并無現(xiàn)成循環(huán)水池,因此我司設(shè)計在該集水池邊再行制作一個3米×4米×1.5米的循環(huán)池,池中分為廢水收集區(qū)及沉降排放池;隨后在該循環(huán)池邊上安裝1臺電解廢水凈化裝置進行處理,處理后的循環(huán)水流入沉降排放池用于下次清洗,并且設(shè)置1套壓濾裝置用于去除沉降濾渣,系統(tǒng)處理流程如下:
When the wastewater recycling method is adopted, circulating water is used for pre-cleaning, and clean water is used for final flushing. The rinsed wastewater enters the circulation system as supplementary water. The designed treatment capacity of the circulation system is 5m3/d. Because there is no existing circulating pond on site, so our company designed another 3m×4m×1.5m circulating pond beside the collecting pond. The pond is divided into a waste water collection area and a sedimentation discharge area; then an electrolytic waste water purification device is installed beside the circulating pond for treatment, the treated circulating water flows into the sedimentation discharge pond for the next cleaning, and a filter press device is set to remove the sedimentation filter residue. The system processing flow is as follows:
4.2.3預(yù)期效果
4.2.3 Expected Effect
1.通過上述改造后,將保持循環(huán)水不發(fā)臭。
- After the above transformation, the circulating water will not be odorous.
2.通過上述改造后,循環(huán)水可持續(xù)循環(huán)使用,無需排放。
- After the above transformation, the circulating water can be used recyclly without discharge.
3.廢水處理機能夠完全替代投加絮凝劑,并且產(chǎn)生的廢渣量較小、自動化程度高,廢渣容易清理。
- The highly-automated waste water treatment machine can completely replace the role of flocculant, the amount of waste residue produced is small and easily to be cleaned.
4.3 廢氣預(yù)處理系統(tǒng)
4.3 Exhaust Gas Pretreatment System
4.3.1三級過濾器
4.3.1 Three-stage Filter
油漆廢氣含有較多的顆粒物,廢氣中的顆粒物會在沸石材料表面不斷的堆積、聚集,不斷增加的顆粒物會影響轉(zhuǎn)筒濃縮裝置的凈化效果,為了保護沸石轉(zhuǎn)筒的吸附凈化性能,有機廢氣進入濃縮裝置之前必須經(jīng)過過濾器,考慮到系統(tǒng)的壓力損失以及濃縮轉(zhuǎn)筒對顆粒物濃度的要求,在沸石轉(zhuǎn)輪前端設(shè)有三級袋式過濾器,過濾等級分別為G4、F7、F9,不同等級過濾器為模塊化設(shè)計,組裝方便。
Paint waste gas contains a lot particulates, which will continue to accumulate on the surface of the zeolite material. The increasing particulates will affect the purification effect of the drum concentration device. In order to sustain the adsorption and purification performance of the zeolite drum. Organic waste gas must pass through a filter before entering into the concentration device . Considering the pressure loss of the system and the requirement of the concentration drum for the concentration of particulates, a three-stage bag filter is installed at the front of the zeolite wheel. The filtration grades are G4, F7, F9. The filter adopts a modular design with different grades and easily to be assembled.
在過濾器前后設(shè)置壓差計根據(jù)壓差的變化來確定更換周期,保證廢氣處理系統(tǒng)正常、安全、穩(wěn)定運行。
Differential pressure gauges are installed at the front and rear of the filter to determine the replacement cycle according to the change of the pressure difference to ensure the normal, safe and stable operation of the exhaust gas treatment system.
4.4 濃縮系統(tǒng)
4.4 Concentration System
廢氣風量
Exhaust air volume
150000m3/h
150000m3/h
廢氣進氣濃度
Inlet Exhaust Gas Concentration
50mg/m3(最高)
50mg/m3 (maximum)
濃縮倍率
Concentration rate
30
30
凈化效率
Purification efficiency
95%
95%
廢氣進氣溫度
Inlet Exhaust gas temperature
常溫(<30℃)
Normal temperature (<30℃)
脫附所需風量
Air volume required for desorption
5000m3/h
5000m3/h
脫附所需溫度
Temperature required for desorption
180±5℃
180±5℃
濃縮廢氣濃度
Concentration of concentrated waste gas
1.27±0.25g/m3(最高)
1.27±0.25g/m3 (maximum)
型號
model
HRH-1524,一共72塊800H模塊
HRH-1524, 72 pieces of 800H modules in total
本方案轉(zhuǎn)筒參數(shù)一覽表
Drum Parameters List for This Scheme
眾所周知沸石材料是整個濃縮裝置的核心, 本設(shè)備采用世界最先進沸石轉(zhuǎn)筒技術(shù)和最高效的沸石模塊,作為裝置核心的沸石模塊是由多層沸石紙疊放成蜂窩狀的成型模塊。
As we known that zeolite material is the core of the entire concentration device. This equipment adopts the world’s most advanced zeolite drum technology and the most efficient zeolite module. As the core of the device, the zeolite module is a honeycomb shaped module made of multiple layers of zeolite paper.
這種沸石紙是使用業(yè)界最先進的濕式抄紙法工藝,把粉末狀的沸石和骨骼纖維及粘合劑(有機,無機)制成瓦楞狀紙張(見下圖)。
This zeolite paper uses the industry’s most advanced wet papermaking process to mix powdered zeolite, bone fibers and binders (organic, inorganic) into corrugated paper (see the picture below).
這樣就連骨骼纖維的間隙中都含有沸石,所以紙中含有的沸石總量將會增加,而且還具有很難讓沸石脫落的特性。
In this way, zeolite is contained even in the gaps between the bone fibers, so the total amount of zeolite contained in the paper will increase, and zeolite is hard to fall off.
沸石含量的比率越高,不僅沸石模塊具有更強的吸附脫附有機溶劑,水分等的能力,而且相對于骨骼纖維來說熱容量低的沸石的比率越高,模塊在吸附濃縮系統(tǒng)中的加熱脫附能耗效率會大步提升。
The higher ratio of zeolite content, the zeolite module has stronger ability to adsorb and desorb organic solvents, moisture, etc.Compared with bone fiber, the higher ratio of zeolite with low heat capacity, the heating energy efficiency and desorption of the module get higher in the adsorption concentration system.
沸石模塊的沸石含有率在75~80wt%是世界最高的,所以比第二位(50wt%)的能耗效率提升30%以上。
The zeolite content rate of the zeolite module is the highest in the world with 75~80wt%, so it is more than 30% higher than the No. 2 energy efficiency (50wt%) .
實現(xiàn)高倍濃縮(見下圖),單臺可處理風量的最大化,充分實現(xiàn)節(jié)能運行。
Achieve high concentration (see figure below), maximize the air volume that can be handled by a single unit, and fully realize energy-saving operation.
4.5 催化燃燒器
4.5 Catalytic Combuster
催化裝置參數(shù)表
Catalytic device parameter table
HR數(shù)量
HR quantity
1套
1 set
轉(zhuǎn)筒轉(zhuǎn)速
Rotating speed of drum
3rph
3rph
CO處理實際廢氣風量
Actual exhaust gas volume for CO treatment
5000Nm3/h(轉(zhuǎn)筒脫附氣)
5000Nm3/h (rotating drum desorption gas)
CO處理設(shè)計廢氣風量
Designed exhaust gas volume for CO treatment
5000Nm3/h
5000Nm3/h
CO廢氣VOC去除率
CO exhaust gas VOC removal rate
≥98%
≥98%
換熱器換熱效率
Heat exchanger efficiency
60%
60%
CO氧化室溫度
CO oxidation chamber temperature
350 ℃
350 ℃
4.6 控制系統(tǒng)
4.6 Control System
本控制系統(tǒng)專為三級過濾+濃縮轉(zhuǎn)筒+催化燃燒裝置系統(tǒng)設(shè)計,根據(jù)工藝要求,采用現(xiàn)場手動控制 、自動控制兩種模式。
This control system is specially designed for the three-stage filtration, concentration drum and catalytic combustion device system. According to the process requirements, it adopts two modes as on-site manual control and automatic control.
現(xiàn)場手動模式:觸摸屏操作界面上的“手動/自動”開關(guān)選擇“手動”方式時,可通過觸摸屏操作界面上的按鈕實現(xiàn)對單個設(shè)備的“運行”或“停止”操作,也可通過現(xiàn)場操作進行必要的手動控制,同時可滿足系統(tǒng)主要設(shè)備檢修及維護的需要。
On-site manual mode: Selects the “manual” mode by touching “manual/automatic” switch on the touch screen operation interface, the button on the touch screen operation interface can be used to realize the “run” or “stop” operation of a single device, or it can be operated on site by manual control to meet the needs of repairing and maintenance.
自動模式:觸摸屏操作界面上的“手動/自動”開關(guān)選擇“自動”方式時,系統(tǒng)設(shè)備的安全由觸摸屏根據(jù)廢氣系統(tǒng)的實際工況及生產(chǎn)要求來完成對整套設(shè)備或單個設(shè)備的“運行”或“停止”控制,而不需要人工干預(yù),從而最大限度的實現(xiàn)了系統(tǒng)的自動運行,減少人員配置,為廢氣處理系統(tǒng)的經(jīng)濟運行提供保證。
Automatic mode: When press the “Manual/Automatic” switch on the touch screen operation interface and select the “Automatic” mode, the safety of the system equipment is controlled by the touch screen according to the actual working conditions and production requirements of the exhaust system, and determines the “Run” or “Stop” of the system or single equipment without manual intervention, thereby maximizing the automatic operation of the system, reducing personnel allocation, and providing a guarantee for the economic operation of the exhaust gas treatment system.
4.7自動控制過程及說明
4.7 Automatic Control Process and Description
按自動運行按鈕啟動設(shè)備后,閥門位置檢查確認。
After pressing the automatic operation button to start the equipment, the valve position is checked and confirmed.
廢氣進氣閥開或關(guān)(根據(jù)預(yù)熱溫度控制)。
The exhaust gas inlet valve is opened or closed (controlled according to the preheating temperature).
新風補充閥開或關(guān)(根據(jù)催化溫度控制)。
The fresh air supplement valve is opened or closed (controlled according to the catalytic temperature).
熱交換旁路閥開或關(guān)(根據(jù)脫附溫度及預(yù)熱溫度控制)。
The heat exchange bypass valve is opened or closed (controlled according to the desorption temperature and preheating temperature).
脫附溫度調(diào)節(jié)閥開或關(guān)(根據(jù)脫附溫度控制)。
The desorption temperature regulating valve is opened or closed (controlled according to the desorption temperature).
閥門延時1分鐘檢測,若檢測異常則報警。
The valve is detected with a delay of 1 minute, and if the detection is abnormal, alarm occurs.
閥門檢測正常,吸附風機啟動,轉(zhuǎn)筒馬達啟動,CO排風機及脫附風機啟動,閥門切換。
The valve detection is normal, the adsorption fan start, the drum motor start, the CO exhaust fan and the desorption fan start, and the valve is switched.
CO排風機及脫附風機啟動,壓力檢測延時60秒,若檢測異常則報警;
The CO exhaust fan and the desorption fan are started, and the pressure detection is delayed for 60 seconds. If the detection is abnormal, the alarm occurs;
CO風機和脫附風機啟動后,進行壓力檢測正常后,吹掃3分鐘后燃燒器依次實施爐膛清掃、點火、升溫、正常工作,根據(jù)催化燃燒預(yù)熱溫度設(shè)定值控制加熱;
After the CO fan and the desorption fan are started with a normal pressure test result. ?the combustor will perform furnace cleaning, ignition, heating, and normal operation after 3 minutes of air purging. The heating is controlled according to the set value of the catalytic combustion preheating temperature.
溫度調(diào)節(jié):*:>350℃燃燒器停止運行,
Temperature adjustment: *: >350℃ the combustor stops running,
*:<350℃時,燃燒機按溫度大小調(diào)節(jié)運行。
*: <350℃, the combustor will operate adjustly according to the temperature.
燃燒機若啟動異常則自鎖停止并報警。
If the combustor starts abnormally, it will get self-locking, stopping and alarming.
閥門運行(當壓力檢測正常后運行,閥門最大100%和最小0%,開度可由PLC程序限位。)
Valve operation (when the pressure detection is normal, the valve will start to operate, the valve opening is between 100% maximum and 0% minimum, the opening can be limited by the PLC program.)
進氣閥:
Inlet valve:
當預(yù)熱溫度≧設(shè)定值廢氣進氣閥逐漸開大。
When the preheating temperature is greater than or equal to the set value, the exhaust gas inlet valve is gradually opened.
當預(yù)熱溫度<設(shè)定值廢氣進氣閥逐漸關(guān)小。
When the preheating temperature is less than the set value, the exhaust gas inlet valve gradually closes.
新風補充閥:
Fresh air supplement valve:
當催化溫度≧設(shè)定值時,新風補充閥逐漸開大;
When the catalytic temperature is greater than or equal to the set value, the fresh air supplement valve gradually opens;
新風補充閥逐漸關(guān)??;
The fresh air supply valve gradually closes;
脫附溫度調(diào)節(jié)閥:
Desorption temperature regulating valve:
實際溫度<脫附溫度設(shè)定值:
Actual temperature < Desorption temperature setting value:
脫附溫度調(diào)節(jié)閥開大,以提高熱風溫度;
Open the desorption temperature control valve to increase the hot air temperature;
實際溫度>脫附溫度設(shè)定值:
Actual temperature>Desorption temperature setting value:
脫附溫度調(diào)節(jié)閥關(guān)小,以降低熱風溫度;
The desorption temperature control valve is closed to reduce the temperature of the hot air;
換熱旁路閥:
Heat exchange bypass valve:
當脫附溫度≤設(shè)定值且預(yù)熱溫度小于310℃,換熱旁路閥根據(jù)脫附溫度設(shè)定值控制,脫附溫度<設(shè)定值換熱旁路閥關(guān)??;
When the desorption temperature is less than the set value and the preheating temperature is less than 310℃, the heat exchange bypass valve is controlled according to the set value of the desorption temperature, and the bypass valve is closed when the desorption temperature is less than the set value;
當脫附溫度≧設(shè)定值且預(yù)熱溫度>310℃,換熱旁路閥根據(jù)預(yù)熱溫度設(shè)定值控制。
When the desorption temperature is greater than or equal to the set value and the preheating temperature is greater than 310℃, the heat exchange bypass valve is controlled according to the set value of the preheating temperature.
當脫附溫度大于設(shè)定值且預(yù)熱溫度≤設(shè)定值時,換熱旁路閥開大;
When the desorption temperature is greater than the set value and the preheating temperature less than or equal to the set value, the heat exchange bypass valve opens;
當脫附溫度大于設(shè)定值且預(yù)熱溫度≧設(shè)定值時,換熱旁路閥關(guān)??;
When the desorption temperature is greater than the set value and the preheating temperature is greater than or equal to the set value, the heat exchange bypass valve is closed;
轉(zhuǎn)筒運行
Drum operation
轉(zhuǎn)筒是連續(xù)運轉(zhuǎn)的,每小時約3圈,在設(shè)備調(diào)試初期即確定轉(zhuǎn)速,正常運行時不需更改轉(zhuǎn)速。
The drum runs continuously, about 3 turns per hour. The speed is determined at the early stage of equipment configration, and there is no need to change the speed during normal operation.
發(fā)生異常
Abnormal occurs
若設(shè)備發(fā)生異常:則聲光報警輸出,操作人員應(yīng)立即查看報警原因,做好應(yīng)急準備。
If the equipment is abnormal: sound and light alarm occur, the operator should check the cause of the alarm immediately and prepare for the emergency.
停機
Shut-down
按自動停止按鈕后,燃燒器根據(jù)停機延時設(shè)定值自動停止。
After pressing the automatic stop button, the combustor will automatically stop according to the stop delay setting value.
當爐膛溫度>100℃時, CO排風機、脫附風機、吸附風機、轉(zhuǎn)筒馬達保持運行;
When the furnace temperature is more than 100℃, the CO exhaust fan, desorption fan, adsorption fan and drum motor keep running;
當爐膛溫度≤100℃時,CO排風機及脫附風機停止工作,而吸附風機、轉(zhuǎn)筒馬達再根據(jù)吸附風機停機延時自動停止。
When the furnace temperature is less than or equal to 100℃, the CO exhaust fan and desorption fan stop working, and the adsorption fan and drum motor will automatically stop according to the stop delay of the adsorption fan.
4.8 電氣及自控安全措施
4.8 Electrical and Automatic Control Safety Measures
本項目電控系統(tǒng)設(shè)計是以PLC自動控制為核心,包括人機界面操作中心、安全聯(lián)鎖、聲光報警等,并配置適當?shù)闹甘緹艉涂刂瓢粹o為輔助。
The design of the electronic control system of this project is based on PLC automatic control, including man-machine interface operation center, safety interlock, sound-light alarm and etc., and equiped with appropriate indicator lights and control buttons as auxiliary.
(1)根據(jù)工藝要求改變控制參數(shù)。
(1) Change the control parameters according to the process requirements.
(2)自動運行時具有連鎖功能。
(2) ?interlocking function is available during automatic operation.
(3)自動運行時可根據(jù)工藝條件退出運行
(3) The operation can be exited according to the process conditions during automatic operation
(4)系統(tǒng)具有自我診斷功能,運行時出現(xiàn)的異常情況可報警及自動停機。
(4) The system has a self-diagnosis function, which can alarm and stop automatically when abnormal conditions occur during operation.
(5)系統(tǒng)運行時采用PLC程序全自動控制,且具有記憶功能,當系統(tǒng)停運后再啟動時可根據(jù)上次的運行狀態(tài)自動選擇運行模式。
(5) The system adopts PLC program for full-automatic control in running and has a memory function. When the system is stopped and restarted, the running mode can be automatically selected according to the last running state.
1、電源:主電源380V±5%、3相、50HZ,采用三相五線制供電。
- Power supply: the main power supply is 380V±5%, three-phase, 50HZ, adopts three-phase five-wire system.
2、控制柜的技術(shù)要求:
- Technical requirements of the control cabinet:
(1)為了保持柜內(nèi)溫度低于各元件允許的最高溫度,要提供強制的通風;風扇電源為220V,50HZ,風扇要有防護手指免受傷害措施,噪聲要滿足標準要求,風扇要用可拆清洗式的濾網(wǎng)。
(1) In order to keep the temperature in the cabinet below the maximum allowable temperature of each component, ventilation must be provided; the fan power supply is 220V, 50HZ, the fan with removalable cleaning filter must have measures to protect fingers from injury, and the noise must meet the standard requirements,
(2)控制柜要留有20%安裝空間,以備將來增加元件之用,控制柜內(nèi)的結(jié)構(gòu)和所有內(nèi)部連線要符合有關(guān)標準的具體要求。
(2) 20% installation space of ?the control cabinet should be reserved to prepare for adding components in the future. The structure and all internal wiring in the control cabinet should meet the specific requirements of relevant standards.
(3)電控柜面板和各操作站面板都必須設(shè)置急停按鈕,操作工位按需要配置急停按鈕。
(3) The panel of the electric control cabinet and the panel of each operation station must be equipped with an emergency stop button, and the operating stand shall be equipped with an emergency stop button as required.
3、PLC主要控制點位:
- PLC Main Control Points:
(1)進出風單元控制
(1) Control of air inlet and outlet units
系統(tǒng)吸附/脫附作業(yè)時,控制設(shè)備進/出風口閥門,及時反饋數(shù)字信號,同時控制吸附/脫附風機的啟停。
During the adsorption/desorption operation of the system, the inlet/outlet valve of the equipment is controlled to feed back digital signals in time, and control the start and stop of the adsorption/desorption fan at the same time.
(2)燃燒單元控制
(2) Combustion unit control
燃燒爐自動升溫控制以及內(nèi)部溫度、壓力、高溫閥連鎖控制。
Automatic heating control of combustion furnace and interlocking control of internal temperature, pressure and high temperature valve.
(3)報警控制
(3) Alarm control
當系統(tǒng)內(nèi)部溫度、壓力超出設(shè)定范圍時,系統(tǒng)會進行相應(yīng)的連鎖反應(yīng)包括聲光報警、強制關(guān)閉系統(tǒng)、啟動應(yīng)急處理單元等。
When the internal temperature and pressure of the system exceed the set range, the system will carry out corresponding chain reactions including sound and light alarm, forced system shutdown, and activation of emergency processing units.
當噴漆室內(nèi)有機溶劑濃度超過設(shè)定值時,立即報警,送排風系統(tǒng)繼續(xù)工作,報警方式為聲光報警。
When the concentration of the organic solvent in the painting room exceeds the set value, sound and light alarm occurs immediately, and the air supply and exhaust system will continue to work.
4、在失電情況下的保護措施:
- Protective Measures in Power Loss:
(1)電源切斷或設(shè)備急停時,為避免設(shè)備損壞或人身傷害,不允許設(shè)備運動執(zhí)行元件有任何運動。
(1) When the power supply is cut off or the equipment is stopped in an emergency, in order to avoid equipment damage or personal injury, no actuator movement of the equipment is allowed.
(2)電控系統(tǒng)及元件必須能夠適應(yīng)工廠電網(wǎng)上的電壓偏差、波動±5%、閃變和各種諧波及脈沖干擾。
(2) The electronic control system and components must be able to adapt to the voltage deviation, ?±5% fluctuation, flicker, and various harmonics and pulse interference cause by the factory power supply.
(3)供電系統(tǒng)有缺相、欠壓時,該系統(tǒng)電源開關(guān)必須隨之自動斷電;在線路中其它電壓干擾,或失電后,被中斷的程序必須能夠重新啟動運行。
(3) When there is phase loss or undervoltage of the power supply system, power switch of the system must be automatically cut off; after the voltage interference or power loss occurs, the interrupted program must be able to be reinitiated.
5、用電設(shè)備的保護:
- Protection of electrical equipment:
(1)每條回路單獨采用漏電、短路、過流保護裝置,每條回路單獨采用過載保護裝置,不允許自動再次接通電源。
(1) Each circuit adopts leakage, short circuit, and overcurrent protection devices separately, and each circuit adopts separate overload protection devices, and it is not allowed to be automatically reinitiated.
(2)限位開關(guān)和各種保護開關(guān)裝置,在回路中使用繼電器去執(zhí)行動作。
(2) Limit switches and various protective switch devices adopt ?relays to perform actions in the loop.
6、我公司PLC自動控制系統(tǒng)的優(yōu)點:
- The advantages of our company’s PLC automatic control system:
(1)可靠性高,抗干擾能力強:PLC系統(tǒng)采用現(xiàn)代大規(guī)模集成電路技術(shù),經(jīng)嚴格的生產(chǎn)工藝制造,內(nèi)部電路也采取了先進的抗干擾技術(shù),具有很高的可靠性,此外,PLC帶有硬件故障自我檢測功能,出現(xiàn)故障時可及時發(fā)出警報信息。
(1) High reliability and strong anti-interference ability: The PLC system adopts modern large-scale integrated circuit technology and is manufactured by strict production technology. The internal circuit also adopts advanced anti-interference technology, which has high reliability. In addition, PLC is desiged With hardware failure self-detection function, an alarm message can be sent in time when a failure occurs.
(2)易學(xué)易懂,操作簡便: PLC系統(tǒng)只使用少量開關(guān)量邏輯控制指令就可以方便地實現(xiàn)繼電器電路的功能,觸摸屏界面,操做簡單。
(2) Easy to learn and easy to operate: The PLC system can easily realize the function of the relay circuit with only a few switching logic control instructions. The touch screen interface is simple to operate.
(3)協(xié)調(diào)控制,配合生產(chǎn):PLC系統(tǒng)與生產(chǎn)線聯(lián)動,控制各環(huán)節(jié)調(diào)節(jié)閥門,實現(xiàn)“信號反饋及時,反應(yīng)操作迅速”的控制模式。
(3) Coordinated control and production: The PLC system is linked with the production line to operate each control valve, and realize the control mode of “timely signal feedback and rapid response”.
(4)預(yù)防報警,應(yīng)急控制:當系統(tǒng)內(nèi)部壓力、溫度超出設(shè)定范圍,信號及時反饋中央CPU,同時聲光報警、緊急停機制動,確保整個系統(tǒng)的安全。
(4) Preventive alarm and emergency control: When the internal pressure and temperature of the system exceed the set range, the signal will be fed back to the central CPU in time, meanwhile sound and light alarms occur, and emergency stop is triggered to ensure the safety of the entire system.
(5)調(diào)節(jié)模式,節(jié)能控制:PLC會根據(jù)整套系統(tǒng)的開啟、運行、關(guān)閉狀態(tài)自動調(diào)整自身的工作模式,最大限度降低設(shè)備的運行能耗。
(5) Regulation mode, energy-saving control: PLC will automatically adjust its own working mode according to the on-off and running status of the entire system to minimize the energy consumption of the equipment.
4.9 系統(tǒng)特點
4.9 System Features
有機廢氣轉(zhuǎn)筒吸附催化燃燒脫附是將吸附與催化燃燒工藝進行有機的結(jié)合,兼顧了兩者的優(yōu)點,達到優(yōu)勢互補的效果,使其應(yīng)用范圍更廣,治理廢氣更加靈活,運行成本更加低廉。
Organic waste gas rotating drum adsorption and catalytic combustion desorption is an combination of adsorption and catalytic combustion processes, combining the advantages of both method, achieving mutual support effect and popular using, more flexible in waste gas treatment, and lower operating costs .
裝置特點如下:
The features of the device are as follows:
特有的沸石材料保證轉(zhuǎn)筒裝置的高吸、脫附效率,使原本大風量、低濃度的VOCs廢氣,轉(zhuǎn)換成小風量、高濃度的廢氣,便于后段處理。
The unique zeolite material ensures the high absorption and desorption efficiency of the rotating drum device, so that the original large air volume and low concentration of VOCs waste gas can be converted into small air volume, high concentration waste gas, which is convenient for subsequent treatment.
2、沸石轉(zhuǎn)筒吸附VOCs所產(chǎn)生的壓降極低,可大大減少風機電力能耗。
- The pressure drop caused by the adsorption of VOCs by the zeolite drum is extremely low, which can greatly reduce the power consumption of the fan.
3、整體系統(tǒng)采用預(yù)組合模塊化設(shè)計,具備了最小的空間需求,且提供了持續(xù)性及無人化的操控模式。
- The overall system adopts a pre-combined modular design, which has the smallest space requirement and provides a continuous and unmanned control mode.
4、高去除率的轉(zhuǎn)筒裝置設(shè)計保證經(jīng)過轉(zhuǎn)筒濃縮后的廢氣,可達到國家最嚴格的排放標準。
- The design of the drum device with high removal rate ensures that the exhaust gas through the drum can meet the strictest national emission standards.
5、模塊化設(shè)計,使轉(zhuǎn)筒設(shè)備的維護和材料的再生簡單易行。
- Modular design makes the maintenance of the drum equipment and the regeneration of materials simple and easy.
6、催化燃燒與直接燃燒相比具有起燃溫度低,能耗也小的顯著特點。
- Compared with direct combustion, catalytic combustion has the remarkable characteristics of low light-off temperature and low energy consumption.
在廢氣濃度高的情況下,達到起燃溫度后便無需外界供熱。
In the case of high exhaust gas concentration, external heating is not required after reaching the light-off temperature.
7、處理效率高(>85%),最終產(chǎn)物為無害的CO2和H2O(雜原子有機化合物還有其他燃燒產(chǎn)物),因此無二次污染問題。
- High treatment efficiency (>85%), and the final products are harmless CO2 and H2O (heteroatomic organic compounds and other combustion products), so there is no problem of secondary pollution.
由于溫度低,能大量減少NOX的生成。
Due to the low temperature, the production of NOX can be greatly reduced.
4.10 排氣煙囪
4.10 Exhaust Chimney
排風煙囪底部(0-10m)采用12mm鋼板制作,(10-20m)采用10mm鋼板制作,(20-32m)采用8mm鋼板制作,設(shè)置錐形風帽,鋼材表面處理后外涂防銹底漆及面漆,底部3 米高度用耐高溫巖棉做外保溫,外包鍍鋅鐵皮。
The bottom of the exhaust chimney (0-10m) is made of 12mm steel plate, (10-20m) made of 10mm steel plate, (20-32m) made of ?8mm steel plate, and equipped with a conical hood, the surface of the steel is covered with anti-rust primer and top coat, the 3 meters bottom is coated with high temperature resistant rock wool for external insulation, which is covered with galvanized iron sheet.
煙囪固定方式:底部與煙囪基礎(chǔ)螺栓連接與焊接相結(jié)合,外包鍍鋅鐵皮,煙囪底部3米使用耐高溫巖棉保溫,煙囪周圍設(shè)置旋轉(zhuǎn)樓梯及框架并采用纖繩固定,15米高度處設(shè)置采樣平臺。
Chimney fixing method: the bottom of the chimney is fixed by a combination of foundation bolts and welding, and coated with galvanized iron. The 3 meters bottom of the chimney is insulated with high temperature resistant rock wool. A spiral staircase and frame are set around the chimney and fixed with fiber ropes. A sampling platform is set at a height of 15 meters. .
4.12 VOCs治理設(shè)施運行監(jiān)控儀
4.12 VOCs treatment Facility Operation Monitor
上海市生態(tài)環(huán)境局頒發(fā)《關(guān)于開展本市重點行業(yè)揮發(fā)性有機物綜合治理工作》通知中,企業(yè)有項任務(wù)是對標對表,完成VOCs綜合治理“一廠一方案(2.0)”工作,各企業(yè)都應(yīng)積極采取管控措施減少VOCs排放,從源頭替換、過程控制到末端治理,甚至運行監(jiān)控都將VOCs治理理念滲透到各環(huán)節(jié),把VOCs減排工作做細做好。
In the notice issued by the Shanghai Municipal Bureau of Ecology and Environment on “the Comprehensive Treatment of Volatile Organic Compounds in Key Industries in Shanghai”, the company’s tasks meet the standards and complete the VOCs comprehensive treatment plan. All companies should actively take effective control measures to reduce VOCs emission .
在運行管理環(huán)節(jié)以下幾點是要重點保證的:
The following points must be ensured in the operation management:
設(shè)定控制指標,并劃定正常運行的范圍限值;
Set the control index and fix the range limit in normal operation;
連續(xù)測量并記錄治理設(shè)施控制指標溫度、壓力(壓差)、時間和頻率值;
Continuously measure and record the temperature, pressure (pressure difference), time and frequency values of the control indicators of the treatment facility;
總用電量瞬時值和累計值連續(xù)測量記錄;
Continuously measure and record the instantaneous value and accumulated value of total power consumption;
發(fā)生故障時將故障報警信息及時報送并設(shè)置明顯故障標識。
When a failure occurs, the failure alarm information must be reported in time and an obvious failure identification must be set.
根據(jù)環(huán)保相關(guān)要求,以及我方以往項目經(jīng)驗的經(jīng)驗,我方開發(fā)了VOCs治理設(shè)施運行監(jiān)控儀,其將整個系統(tǒng)的各項運行參數(shù)集中收集整合,方便運行管理人員能夠及時、有效、便捷的監(jiān)控、掌握整個系統(tǒng)的運行情況,其主要監(jiān)控參數(shù)見表1。
According to environmental protection requirements and previous experience, we have developed a VOCs treatment facility operation monitor, which collects and integrates various operating parameters of the entire system, so that operation managers can monitor in a timely, effective and convenient manner. Master the operation status of the entire system, the main monitoring parameters are shown in Table 1.
表1 VOCs治理設(shè)施運行監(jiān)控儀監(jiān)控內(nèi)容
Table 1 Content of VOCs treatment facility operation monitor
設(shè)備及設(shè)施
Equipments and facilities
監(jiān)控指標
Monitoring indicators
噴漆房
Paint Booth
室內(nèi)溫濕度
Indoor temperature and humidity
VOCs治理設(shè)備
VOCs Treatment Equipment
1.處理風量2.設(shè)施用電量
- Air volume handled 2. Electricity consumption of facilities
換熱器
Heat Exchanger
進出口溫度
Inlet and outlet temperature
濃縮裝置
Concentrator
1.吸附周期2.脫附時間及溫度
- Adsorption cycle 2. Desorption time and temperature
催化氧化器
Catalytic Oxidizer
催化床溫度
Catalytic Bed Temperature
排風風機
Exhaust fan
電機頻率
Motor frequency
排氣筒
Exhaust pipe
出口濃度(對比用)
Outlet concentration (for comparison)
注:除上表中的各項參數(shù)外,也可根據(jù)業(yè)主要求及實際情況增加監(jiān)控項目
Note: In addition to the parameters in the above table, monitoring items can also be added according to the owner’s requirements and actual conditions
所有監(jiān)控內(nèi)容的實時數(shù)據(jù)將直觀的顯示在監(jiān)控儀主界面上(圖1),各并且項數(shù)據(jù)除實時顯示之外,還會以數(shù)據(jù)曲線方式顯示(圖2),其中將顯示實時數(shù)據(jù)、運行曲線、正常運行上下限,并且每張運行曲線圖還可進行放大,放大后的曲線圖可以上下左右拖動查看,并且曲線可以以年、月、日不同時間單位進行顯示。
The real-time data of all monitoring content will be displayed intuitively on the main interface of the monitor (Figure 1). In addition to real-time display, the data of each item will also be displayed in a data curve (Figure 2), which will display real-time data, running curve and upper and lower limits. and each operation curve can be enlarged. The enlarged curve can be dragged up and down for viewing, and the curve can also be displayed in different time units by year, month, and day.
所有數(shù)據(jù)每一天都會生成一個EXCEL文件,若需導(dǎo)出文件可直接拔出SD卡,插入電腦中即可。
All data will be collected and generate an EXCEL file every day, if need to export the file, you can directly pull out the SD card and insert it into the computer.
本設(shè)備有專用通信軟件,能為有需求的用戶配套物聯(lián)網(wǎng)系統(tǒng),提供多組設(shè)備聯(lián)網(wǎng)、云端存儲及手機APP顯示等功能。
This device has specialized communication software, which can support the Internet of Things system for the necessary users, and provide functions such as of multiple sets group networking, cloud storage, and mobile APP display.